Publicación:
Relación entre composición corporal por bioimpedancia con la cantidad máxima de oxígeno estimado y distancia recorrida en metros obtenidos por la marcha de 6 minutos en pacientes de segunda fase de rehabilitación cardíaca del Hospital General de la Plaza de la Salud, enero-mayo 2025

dc.contributor.advisorVioleta González Pantaleón
dc.contributor.advisorSheila Espinal
dc.contributor.authorDaniel Ernesto Núñez Mercedes
dc.contributor.authorRamón Antonio Moricete Saviñón
dc.date.accessioned2025-08-11T15:49:31Z
dc.date.available2025-08-11T15:49:31Z
dc.date.issued2025
dc.degree.areaSalud
dc.degree.levelPostgrado
dc.degree.programMaestría en Medicina Física y Rehabilitación
dc.description.abstract[Español] Introducción: Las enfermedades cardiovasculares representan una carga importante de morbilidad. La rehabilitación cardíaca (RC), particularmente en su segunda fase, busca mejorar la capacidad funcional de los pacientes mediante intervenciones multidisciplinarias. La prueba de marcha de 6 minutos (6MWT) y la bioimpedancia eléctrica son herramientas accesibles y complementarias para evaluar la evolución clínica. Métodos: Estudio observacional, descriptivo, de corte transversal, realizado en el Hospital General de la Plaza de la Salud entre enero y mayo de 2025. Se incluyeron 50 pacientes en fase II de RC, con registros válidos de composición corporal por bioimpedancia y resultados de la 6MWT. Se analizaron relaciones entre masa muscular, grasa visceral, porcentaje de agua corporal e IMC con la distancia recorrida y el VO₂máx estimado. Resultados: Se encontró una relación moderada entre mayor masa muscular y mejor desempeño en la 6MWT. La grasa visceral elevada se asoció a VO₂máx clasificado como "muy pobre". El 50% de los pacientes presentó IMC en sobrepeso u obesidad, pero solo el 32% tenía niveles normales de grasa visceral, indicando riesgo cardiometabólico oculto. Discusión: La composición corporal influye en la capacidad funcional y aeróbica. La bioimpedancia se muestra como una herramienta útil para complementar la evaluación funcional, especialmente en pacientes con adiposidad central no evidenciada por IMC.
dc.description.abstract[English] Introduction: Cardiovascular diseases are a major burden of morbidity. Cardiac rehabilitation (CR), particularly in its second phase, aims to improve patients’ functional capacity through multidisciplinary interventions. The six-minute walk test (6MWT) and bioelectrical impedance analysis (BIA) are accessible and complementary tools for clinical monitoring. Methods: Observational, cross-sectional descriptive study conducted at the Hospital General de la Plaza de la Salud between January and May 2025. Fifty patients in CR phase II with valid BIA and 6MWT records were included. Associations between skeletal muscle mass, visceral fat, body water percentage and BMI with walked distance and estimated VO₂max were analyzed. Results: A moderate relationship was found between higher muscle mass and better performance in the 6MWT. High visceral fat was associated with "very poor" VO₂max. Although 50% of patients were overweight or obese by BMI, only 32% had normal visceral fat levels, indicating hidden cardiometabolic risk. Discussion: Body composition influences functional and aerobic capacity. BIA proves to be a useful tool to complement functional evaluation, especially in patients with central adiposity not detected by BMI.
dc.identifier.citationApellido, Nombre del autor (año). Título del trabajo. [Trabajo final, Maestría en Medicina Física y Rehabilitación]. Santo Domingo: Universidad Iberoamericana (UNIBE). Recuperado de:
dc.identifier.urihttps://repositorio.unibe.edu.do/handle/123456789/2882
dc.language.isoEspañol
dc.publisherSanto Domingo: Universidad Iberoamericana (UNIBE)
dc.rights.licenseAcceso abierto bajo licencia de uso Creative Commons CC BY-NC-ND 4.0 (Atribución-NoComercial-SinDerivadas 4.0 Internacional)
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subjectRehabilitación cardíaca
dc.subjectBioimpedancia
dc.subjectMarcha de 6 minutos
dc.subjectComposición corporal
dc.subjectVO₂máx
dc.subjectCardiac rehabilitation
dc.subjectBioimpedance
dc.subjectSix-minute walk test
dc.subjectBody composition
dc.titleRelación entre composición corporal por bioimpedancia con la cantidad máxima de oxígeno estimado y distancia recorrida en metros obtenidos por la marcha de 6 minutos en pacientes de segunda fase de rehabilitación cardíaca del Hospital General de la Plaza de la Salud, enero-mayo 2025
dc.typeTesis
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
21-1031_TF.pdf
Tamaño:
4.09 MB
Formato:
Adobe Portable Document Format
No hay miniatura disponible
Nombre:
21-1031_FA.pdf
Tamaño:
475.99 KB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.32 KB
Formato:
Item-specific license agreed upon to submission
Descripción: